Main station|Member Center|Save the desktop|Mobile browsing
Ordinary Member

Shenzhen Nanden Chengfang Technology Co

Testing equipment for DC power supplies, including discharge meters, internal...

sell
  • There is no classification
contact
  • Contact:聂方
  • Phone:0755-84033782
  • Email:13824392981@139.com
  • fax:0755-84033782
search
 
link
  • There is no link yet
home > sell > NF33 charger characteristic tester
NF33 charger characteristic tester
products: Views:18NF33 charger characteristic tester 
brand: 南电
price: 面议
MOQ:
Total supply:
Delivery date: Shipped within 3 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2015-07-02 19:25
 
Details
Charger Characteristics Tester
Product Overview
The Charger Characteristics Tester is based on the relevant national requirements of the "DC Power Supply Operation and Maintenance Regulations", integrating years of development results and long-term field operation experience, integrating domestic and foreign A new product developed based on relevant advanced technologies, this device can detect and test the capacity of chargers and battery packs with different capacities, and can accurately and reliably test the voltage stabilization accuracy of the substation DC power supply system, the stabilization accuracy, ripple coefficient efficiency value, AC Enter parameters such as subharmonic value, discharge capacity, etc. It is also equipped with DC power comprehensive tester data analysis software to perform various analyzes on the measurement data uploaded to the computer.
Design Features
◆ It is a special equipment for DC power supply testing and analysis. It can fully automatically complete AC voltage adjustment, loading load resistance parameter test, ripple coefficient test, steady current accuracy test, voltage stabilization accuracy test and other automatic recording tests in accordance with national standards. value and stop testing and other functions.
◆ The powerful expansion function is compatible with DC system and DC system detection.
◆ It adopts three-phase automatic numerically controlled voltage regulator with high output precision, high power and high voltage stability.
◆ Use and dual work control, and byte memory.
◆ The instrument uses a large-screen LCD touch screen and a fully Chinese graphical interface, making the operation simpler and more convenient.
◆ The test data is displayed in real time during the test process, and all charts are clear, beautiful, intuitive and convenient.
◆ The echo measurement data can be saved or uploaded to the dedicated DC power comprehensive tester data analysis software for detailed data chart analysis. Test at any time, save, edit and print at any time.
◆ The data is transferred to the computer for storage management, and long-term historical data preservation and analysis can be carried out.
◆ Modular structure, reasonable design, reliable operation, small size and light weight.
◆ The large-capacity memory stores three hundred sets of data for voltage stabilization accuracy test, ripple coefficient test, current stabilization accuracy test, efficiency test, and current limiting characteristic test.
◆ Complete communication functions, with communication interfaces and interfaces, using the disk to transfer data, and the instrument software can be updated via the disk.
◆ With automatic test protection function, when an abnormality of the entire group or single battery is detected during the test, the test will be automatically terminated.
◆ Prevent over-discharge of the battery, completely avoid impact on the equipment, and also terminate the ongoing test process artificially as needed.
Product functions
Comprehensive test Comprehensive test display, measure DC current, measure DC voltage, measure AC voltage and measure ripple voltage, and calculate the voltage stabilization accuracy, the stabilization accuracy, the voltage ripple coefficient and the ripple coefficient, .
The voltage stabilization accuracy measures the voltage stabilization accuracy when the AC input voltage changes within the rated voltage range, the load current changes between ~ the rated value, and the DC output voltage is at any value within the adjustment range.
Current stabilization accuracy measures the current stabilization accuracy when the AC input voltage changes within the rated voltage range, the output current is at any value ~ the rated value, and the charging voltage changes within the specified adjustment range.
Ripple accuracy measures the ratio of half of the difference between the peak value and the valley value of the pulsation in the DC voltage output by the charging device to the average value of the DC output voltage, and calculates the steady voltage ripple coefficient and steady current ripple coefficient. .
Efficiency measures the ratio of AC rated input power to DC output power of the charging device. Efficiency measurement display measures AC voltage, measures AC current, measures DC voltage, measures DC current, and calculates the input power, output power and efficiency.
Harmonic measurement Current harmonic measurement mainly displays the status of ~ harmonics, including harmonics or fundamental harmonic true effective value, harmonic content rate, total harmonic distortion rate and other parameters.
The powerful data processing function can display curves and generate reports for multiple battery measurement results, and conduct comprehensive calculation and analysis to accurately judge.
The data analysis includes comprehensive analysis of voltage stabilization accuracy analysis, flow stabilization accuracy analysis, ripple coefficient analysis, efficiency analysis, grid harmonic analysis and battery discharge analysis, which can re-display the contents of the original measurement interface.
Data upload This function allows users to upload saved measurement data to the computer for various analyses.
System upgrade This function allows users to update the instrument software using the disk.
Technical indicators
Project host product specifications
/
Load current ~ ~ ~ ~
Applicable voltage level/
Dimensions
Weight
DC voltage measurement~ ~
~
Accuracy voltage and current
Ripple coefficient~
Memory
Power supply
Working environment temperature ℃~℃ Humidity~< br/> Voltage regulator parameters
Rated power and rated current
Input voltage + volume
Output voltage ~ weight
Equipment with different voltage and current levels can be customized according to user needs
Request for quotation
A total of0articles  Related Comments: